Fronius Acctiva Professional Flash User Manual Page 58

  • Download
  • Add to my manuals
  • Print
  • Page
    / 160
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 57
56
Retrieving param-
eters during
charging
The top half of the display shows current progress and the bottom half shows the rele-vant
values.
Deep-discharge
battery: starting
charging manual-
ly
Press the info button during charging
The actual charging current is displayed:
E.g.: actual charging current
By repeated pressing the info button, the other parameters are displayed in the fol-
lowing sequence:
E.g.: actual battery voltage E.g.: amount of charge fed in E.g.: energy fed in
E.g.: length of time
charging so far
CAUTION! Risk of serious damage as a result of incorrectly connected charging
terminals. The reversal polarity protection facility is inoperative if charging is start-
ed manually (battery voltage < 1.0 V).
Connect charging terminals to correct poles and ensure proper electrical connec-
tion to vehicle terminals.
Page view 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 159 160

Comments to this Manuals

No comments