By repeated pressing the info button, the other parameters are displayed in the following
sequence:
Charge accept-
ance test finished
- battery faulty
IMPORTANT! A fully-charged battery can also return a negative test result. In this case the
battery must be discharged (see chapter entitled Charge acceptance test - Preparations).
The charge acceptance test shows that the battery is faulty. The battery receives no further
charge. The result is displayed on the screen:
By pressing the Info button the following parameters can be to retrieved:
E.g.: actual charging current
- the top half of the display features progress bars to show
the progress of the current charging operation
- the bottom half of the display shows the current charging
parameters / calculated test parameters
Charging parameters:
E.g.: actual battery voltage E.g.: amount of charge fed in E.g.: energy fed in
E.g.: length of time charging so far
Test parameters: can be identified by the test symbol
E.g.: charging current E.g.: battery voltage E.g.: set battery capacity
E.g.: Battery’s capacity to accept
charge, expressed in %
E.g.: charging current
- the top half of the display shows „Test Fail“ at a negative
result of the charge acceptance test
- the bottom half of the display shows the calculated para-
meters