Fronius Signal Card
Bedienungs- &
Installationsanleitung
Operating and
Installation instructions
/ Battery Charging Systems / Welding Technology / Solar Electronics
DEENZH
42,0410,1113 003-26042012
Page view 0
1 2 3 4 5 6 ... 38 39

Summary of Contents

Page 1 - Fronius Signal Card

Fronius Signal CardBedienungs- &InstallationsanleitungOperating andInstallation instructions/ Battery Charging Systems / Welding Technology / Sola

Page 2

8Ein Beschalten des Relais ist wie folgt möglich:Relais alsÖffner und alsSchließer- Als Öffner- Als Schließer

Page 3 - Sehr geehrter Leser

9DEGleichzeitigesÜberwachenmehrererWechselrich-terSollten Sie mehrere Wechselrichter mit nur einer Signaleinrichtung (z.B.Lampe) überwachen wollen, kö

Page 4 - Personenschutz

10Folgende Jumper sind für persönliche Einstellungen verfügbar:1. „Buz.“ (on/off) ... Standardeinstellung: „on“2. „Err.“ (perm./all) ... Standardeinst

Page 5 - Inhaltsverzeichnis

11DEDie Anspeisung der Fronius Signal Card erfolgt über die DC-Versorgungdes Wechselrichters. An den Klemmen des Relais angeschlossene Ver-braucher (z

Page 6 - Allgemeines

Technische DatenDer Einsatz einer Fronius Signal Card ist für Wechselrichter ab Serien-nummer 14330071 möglich.Bei älteren Wechselrichtern ist ein Har

Page 7

1ENDear reader,These operating instructions will help you familiarise yourself with theinstallation, operation, care and maintenance of the Fronius Si

Page 8

2Protection of personnelHousingGalvanic (elec-trical) isolati-onThe inverter connection compartment must only be opened by an autho-rised installation

Page 9 - Stromkreis anschließen

3ENContentsDear reader ... 1The op

Page 10

4GeneralThe Fronius Signal Card keeps you up-to-date with the operating status ofyour inverter in real time. It may be used with the following inverte

Page 11

5ENInstallationTo install the Fronius Signal Card, please see the following section in theinverter operating instructions: „Installing plug-in cards“F

Page 13 - Stromversorgung

61. Set the jumper as desired (see „Jumper“ chapter)Fronius IG Plus only:Important! To allow sufficient screwdriver access to the terminal, ensurethat

Page 14 - Anwendungsmöglichkeiten

7ENThe Fronius Signal Card forms the connection to a circuit. The circuit mayinclude elements such as a signalling device and must comply with thefoll

Page 15 - Dear reader

8The relay may be wired as follows:Relay as anNC and NOcontact- As an NC contact- As an NO contact

Page 16 - Protection of personnel

9ENSimultaneousmonitoring ofseveral inver-tersIf you wish to monitor several inverters with just a single signalling device(e.g. light), connect the F

Page 17 - Contents

10The following jumpers are available for individual settings:1. „Buz.“ (on/off) ... Default setting: „on“2. „Err.“ (perm./all) ... Default setting: „

Page 18

11ENPower is supplied to the Fronius Signal Card via the inverter DC supply.However, any consumers (e.g. signalling devices) connected to the relayter

Page 19 - Installation

12Technical dataFronius Signal Cards may be used with inverters from serial number14330071.A hardware update is required for older inverters. Please c

Page 23

1DESehr geehrter LeserDie vorliegende Bedienungsanleitung soll Sie mit Installation, Bedienung,Pflege und Wartung der Fronius Signal Card vertraut mac

Page 24

4(1)(4)(5)(8)(6)(7)(3)(2)(9)

Page 30

10Buz.off onBuz.offonErr.perm. allErr.perm. all

Page 33

ud_fr_se_so_00913 012011Fronius International GmbH4600 Wels, Froniusplatz 1, AustriaE-Mail: [email protected]://www.fronius.comUSAAFronius Worldwi

Page 34

2PersonenschutzGehäuseGalvanischeTrennungDer Anschlussbereich des Wechselrichters darf nur durch lizenzierteInstallateure geöffnet werden.Den Anschlus

Page 35

3DEInhaltsverzeichnisSehr geehrter Leser ... 1D

Page 36

4AllgemeinesDie Fronius Signal Card hält Sie stets über den Betriebszustand IhresWechselrichters auf dem Laufenden und kann mit folgenden Wechselrich-

Page 37

5DEÜbersicht(Fortsetzung)(5) Relais(6) Jumper Servicecode(7) Jumper Summer(8) Summer(9) Zugentlastung für AnschlusskabelInstallationBeachten Sie für d

Page 38

61. Jumper nach Wunsch setzen (siehe Kapitel „Jumper“)Nur bei Fronius IG:Wichtig! Achten Sie bei der Auswahl des Steckplatzes darauf, dass sichrechts

Page 39

7DEDie Fronius Signal Card dient dem Anschließen eines Stromkreises. DerStromkreis kann z.B. eine Signaleinrichtung enthalten und muss folgen-den Merk