Page view 63
56
- assemble AC plug
- connect AC plug to FRONIUS IG unit and latch
Note! Always shut off voltage before unplugging the AC connec-
tion by disconnecting fuse in the house distribution cabinet.
(1) (2) (3)
white: for main cable with
5 to 11 mm diameter
black: for main cable with
9,5 to 15 mm diameter
Connection earth
(yellow/green)
Connect phase
(brown)
Connect zero lead
(blue)
Install the AC plug as follows:
- slide parts (2) and (3) on to the
mains cable as shown in the
illustration below
- connect the mains cable leads
with the AC plug as shown in
opposite illustration
Bare the mains cable as shown in
the illustration for the AC-plug-type
connector
20 mm
5 mm
3. AC plug
connection
and DC plug
(continued)
DC plug example: multicontact plug
- max. current at MC3 = 20 A
- max. current at MC4 = 30 A